Continuous and simultaneous measurement of triple‐oxygen and hydrogen isotopes of liquid and vapor during evaporation experiments

Brady, Matthew P. and Hodell, David A. (2021) Continuous and simultaneous measurement of triple‐oxygen and hydrogen isotopes of liquid and vapor during evaporation experiments. Rapid Communications in Mass Spectrometry. ISSN 0951-4198 DOI https://doi.org/10.1002/rcm.9078

[img] Text
20210225_MPB_RCMS.pdf - Accepted Version
Restricted to Registered users only until 3 March 2022.

Download (1MB) | Request a copy
Official URL: https://doi.org/10.1002/rcm.9078

Abstract

RATIONALE Oxygen and hydrogen isotopes are important tools for studying modern and past hydrological cycle. Previous evaporation experiments use episodic measurement of liquid and/or vapor or have not measured all isotopologues of water. Here, we describe an evaporation experimental system that allows all isotopologues of liquid and water vapor to be measured simultaneously and near‐continuously at high‐precision using cavity ring‐down laser spectroscopy (CRDS). METHODS Evaporating liquid is periodically sampled from a closed recirculating loop by a syringe pump that delivers a constant supply of water to the vaporizer, achieving a water vapor concentration of 20,000 ppmV H2O (±132, 1σ). Vapor is sampled directly from the evaporation chamber. Isotope ratios are measured simultaneously with a Picarro L2140‐I CEDS instrument. RESULTS For liquid measurements, Allan variance analysis indicates an optimum data collection window of 34 minutes for oxygen isotopes and 27 minutes for hydrogen isotopes. During these periods, the mean standard error is ±0.0081 ‰ for δ17O values, ±0.0081 ‰ for δ18O values, and ±0.019 ‰ for δ2H values. For the derived parameters 17O‐excess and d‐excess, the standard error of the mean is 5.8 per meg and 0.07 ‰, respectively. For the vapor phase a 12.5‐minute data window for all isotopologues results in a mean standard error of ±0.012 ‰ for δ17O values, ±0.011 ‰ for δ18O values, and ±0.023 ‰ for δ2H values. For the derived parameters, the standard error of the mean is 9.2 per meg for 17O‐excess and 0.099 ‰ for d‐excess. These measurements result in consistently narrow 95% confidence limits for the slopes of ln(δ17O+1) vs ln(δ18O+1) and ln(δ2H +1) vs ln(δ18O+1). CONCLUSIONS The experimental method permits measurement of fractionation of triple‐oxygen and hydrogen isotopes of evaporating water under varying controlled conditions at high precision. Application of this method will be useful for testing theoretical models of evaporation and conducting experiments to simulate evaporation and isotopic equilibration in natural systems.

Item Type: Article
Uncontrolled Keywords: 2021AREP; IA77
Subjects: 01 - Climate Change and Earth-Ocean Atmosphere Systems
Divisions: 01 - Climate Change and Earth-Ocean Atmosphere Systems
08 - Green Open Access
12 - PhD
Journal or Publication Title: Rapid Communications in Mass Spectrometry
Identification Number: https://doi.org/10.1002/rcm.9078
Depositing User: Sarah Humbert
Date Deposited: 05 Mar 2021 17:43
Last Modified: 05 Mar 2021 17:44
URI: http://eprints.esc.cam.ac.uk/id/eprint/6025